A portable water-cooling system (also referred to as a chiller, cooling unit, or refrigeration machine) is a device designed to continuously transfer heat and generate cooling capacity. It achieves this either through a thermodynamic cycle (specifically, a vapor-compression cycle) involving the compression, condensation, expansion, and evaporation of a refrigerant within a closed loop, or by leveraging the specific properties of water and lithium bromide solutions (in the case of absorption chillers). Its core function is to provide a stable and controllable source of chilled water to air conditioning units, industrial machinery, and laboratory apparatus, thereby serving as the primary cooling source for various industrial processes or environmental control applications.
The system primarily comprises the following core components and concepts: the Compressor (also known as the refrigeration unit, serving as the system's power core and responsible for compressing the refrigerant vapor); the Condenser (a heat exchanger that liquefies the high-temperature, high-pressure gaseous refrigerant, categorized into air-cooled and water-cooled types); the Evaporator (where the liquid refrigerant absorbs heat and evaporates, thereby providing cooling capacity to the circulating water); the Expansion Device (such as an expansion valve, used to reduce the pressure and temperature of the refrigerant); and the Chilled Water Circulation System, which serves as the medium for transporting the generated cooling capacity.
Its fundamental operating principle is based on the refrigeration cycle. In a vapor-compression cycle, low-temperature, low-pressure liquid refrigerant absorbs heat from the circulating water (chilled water) within the evaporator and evaporates, transforming into a low-temperature, low-pressure vapor. This vapor is then drawn into the compressor and compressed into a high-temperature, high-pressure gas. Subsequently, within the condenser, this gas releases its heat to a cooling medium (either water or air) and condenses back into a high-pressure liquid. After passing through the expansion device-where its pressure and temperature are reduced-this high-pressure liquid reverts to a low-temperature, low-pressure liquid-vapor mixture before re-entering the evaporator to begin a new cycle . Concurrently, the chilled water-having been cooled within the evaporator-is pumped to the equipment requiring cooling; after absorbing heat and rising in temperature, it returns to the evaporator to be re-cooled, thereby establishing a continuous supply of cooling capacity.