Low Temperature Water Chiller

Send Inquiry
Low Temperature Water Chiller
Details
Let me explain how this low temperature water chiller works. It has a refrigerant cycle system. Liquid refrigerant in the evaporator absorbs heat from the water. The water gets cold. The refrigerant turns into gas after absorbing heat. The compressor pulls in this gas and compresses it into high-temperature, high-pressure gas.
Category
Industrial Cooling Unit
Share to
Description
modular-1
Below Zero Cooling

Our company has its own R&D team. Our engineers have worked for over ten years. We have worked with Sanyo (Japan) for a long time. Our compressors are all good quality. This low temperature water chiller can drop water temperature below zero. The lowest can reach minus 30 degrees. It is different from ordinary chillers. Ordinary chillers usually only go down to 5 to 10 degrees. This one is for factories that need low-temperature processes. Last year, a chemical factory in Jiangsu contacted us. They had a reactor. The reaction generated heat. The temperature had to be kept at minus 5 degrees. Otherwise, the product would spoil. They used another brand of chiller before, but the water temperature only went down to 5 degrees. That was not enough. So we installed an ATX-08D product for them. Its cooling capacity is 7.83 kW, which is 6,732 Kcal/h. Input power is 8.6 kW. Max running current is 15.8 A. Power supply is 380V three-phase. R22 refrigerant charge is 3.5 kg times 2. It uses a fully enclosed scroll compressor with power 3 kW times 2. Cooling air flow is 8,000 m³/h. Chilled water flow is 3.75 m³/h. The chilled water tank is 0.17 m³. The water pipe size is G1-1/2 inches. After installation, the reactor temperature stayed stable at minus 5 degrees. The product pass rate increased from 70% to 95%. The customer said this machine saved his orders.

 

How It Works

 

Let me explain how this low temperature water chiller works. It has a refrigerant cycle system. Liquid refrigerant in the evaporator absorbs heat from the water. The water gets cold. The refrigerant turns into gas after absorbing heat. The compressor pulls in this gas and compresses it into high-temperature, high-pressure gas. Then it sends the gas to the condenser to release heat. After releasing heat, it turns back into liquid. Then it goes through an expansion valve and becomes low-temperature, low-pressure liquid. It returns to the evaporator to absorb heat again. This cycle repeats. The water gets colder and colder. Our models include ATX-03D, ATX-05D, ATX-08D, ATX-10D, ATX-15D, ATX-20D, ATX-30D, and ATX-40D. The smallest, ATX-03D, has a cooling capacity of 2.92 kW and weighs 130 kg. The largest, ATX-40D, has 34.2 kW cooling and weighs 1,100 kg. For example, ATX-15D has 16.47 kW cooling, input power 17 kW, and a chilled water tank of 0.26 m³.

18

 

Customer Support

 

Many customers ask us questions. First, how long is the warranty? Free warranty. We repair and replace original parts for free. Second, can you customize? Yes, we support OEM and ODM. You bring your drawings, and we make them. Customization takes one to two months. Third, can I order just one unit? Yes. Fourth, do you do a full check before shipping? Yes, we test every machine 100% before it leaves the factory. Our factory has pressure testers, efficiency testers, and temperature calibrators. We test every one. Fifth, what if parts break during shipping? We check what is broken. If a part is crushed, we send a new part. We make 1,200 units per month. Standard machines ship in 15 days. Our idea with this low temperature water chiller is to help factories that need below-zero processes stop worrying about finding the right equipment.

 

Specification Table

 

Parameter

Unit

ATX-03D

ATX-05D

ATX-08D

ATX-10D

ATX-15D

ATX-20D

ATX-30D

ATX-40D

Cooling capacity (50HZ)

KW

2.92

4.68

7.83

10.98

16.47

21.96

27.18

34.2

Cooling capacity (50HZ)

Kcal/h

2514

4023

6732

9440

14160

18881

23369

29405

Input power

KW

3.6

4.8

8.6

9.6

17

22.8

33.7

42.8

Max running current

A

8.8

13.4

15.8

26.7

41.3

55.4

76.8

97.5

Power supply

-

3N-380V 50HZ

Same

Same

Same

Same

Same

Same

Same

Refrigerant

-

R22

R22

R22

R22

R22

R22

R22

R22

Refrigerant charge

KG

2.7

4.3

3.5*2

4.3*2

6.5*2

8.5*2

8.3*3

8.5*4

Refrigerant control

-

Capillary

Capillary

Capillary

Capillary

Capillary

Capillary

Capillary

Capillary

Compressor type

-

Hermetic scroll or piston

Same

Same

Same

Same

Same

Same

Same

Compressor power

KW

2.25

3.75

3*2

3.75*2

5.5*2

7.5*2

7.5*3

7.5*4

Cooling air flow

M³/h

3000

5000

8000

10000

15000

20000

30000

40000

Chilled water flow

M³/h

1.44

2.4

3.75

4.82

7.6

10.16

15

19.53

Chilled water tank

0.07

0.07

0.17

0.17

0.26

0.33

0.4

0.61

Water pipe size

-

G1"

G1"

G1-1/2"

G2"

G2"

G2"

G2-1/2"

G2-1/2"

Water pump power

KW

0.375

0.75

0.75

1.5

1.5

2.2

4

4

Water pump pressure

Kpa

242

290

290

205

205

220

250

250

Length

MM

945

1033

1470

1470

1680

1950

2080

2565

Width

MM

565

613

710

710

890

950

1000

1220

Height

MM

1400

1400

1600

1600

1830

1940

2055

2310

Weight

KG

130

175

270

350

520

590

880

1100

Hot Tags: low temperature water chiller, China low temperature water chiller manufacturers, factory