Saves Electricity Bill
Our company has a habit. Before we release a new machine, we calculate one thing. How much electricity does this machine save compared to the previous generation? How much does it save compared to competitors? For this water chiller cooler, we did the math. It saves an average of 25% electricity compared to an air-cooled unit of the same cooling capacity. Why does it save electricity? Because it uses a shell-and-tube condenser. Water conducts heat much more efficiently than air. An electronics factory in Shaoxing, Zhejiang did the math. Their clean workshop had eight placement machines. These machines have a strict temperature requirement. 24 degrees plus or minus 1 degree. Before, they used air-cooled units. Their electricity bill in summer was 32,000 RMB per month. Later they switched to our ATX-35WT water chiller cooler. This machine has a cooling capacity of 117.28 kW. Total input power is 29.4 kW. Max running current is 65.4 A. Power supply is 380V three-phase. R22 refrigerant charge is 6.2 kg times 3. It uses a fully enclosed scroll compressor with power 9 kW times 3. Cooling water flow is 25.22 m³/h. The chilled water tank is 0.55 m³. The water pipe size is G2-1/2 inches. After connecting to the cooling tower, the first month's electricity bill dropped to 21,000 RMB. They saved 11,000 RMB. Over a year, that is over 100,000 RMB saved. The customer said this machine gives them money.
Quiet and Smart
This product has another benefit besides saving electricity. It is quiet. We add soundproofing cotton to the shell. We also use shock pads for the compressor. Operating noise is only 65 decibels. That is 10 decibels lower than an air-cooled unit. Workers in the clean workshop said it is much more comfortable. Our models range from ATX-20WD to ATX-60WE. The ATX-60WE has a cooling capacity of 198.12 kW, input power 59 kW, and weight 1,100 kg. The ATX-40WF has 129.06 kW cooling, input power 33.1 kW, and a cooling water pipe size of G3 inches. Every machine comes with a PLC controller and a touch screen. The screen shows real-time electricity costs. Customers can clearly see how much electricity they used in a day.

Installation and Payment
The most common question customers ask is: Can you send someone to guide installation? Yes, we can. We have in-sales service. After the order is confirmed, we arrange an engineer to come to your site. He teaches your workers how to connect pipes, how to connect wires, and how to test the machine. We do not charge for this service. Another question: Do you accept third-party inspections? Yes, we do. Customers can send their own people or hire an agency like SGS. Our factory is always open for inspections. We have our own R&D team. Our core engineers have worked in refrigeration for over ten years. We work with Schneider (France). Our controllers are from Schneider. Before every machine leaves the factory, we do an energy efficiency test. The data from the energy efficiency tester is kept in our files for three years. Minimum order is one unit. For custom products, deposit is 50% to 70%. For standard products, deposit is 50%, and the rest is paid before shipment. For export packaging, we order from a professional box factory. Wooden boxes have anti-vibration foam inside. With this water chiller cooler, we want to help customers reduce their electricity bills. Real savings.
Specification Table
|
Parameter |
Unit |
ATX-20WD |
ATX-25WD |
ATX-30WT |
ATX-35WT |
ATX-40WF |
ATX-45WF |
ATX-50WF |
ATX-60WE |
|
Cooling capacity (50HZ) |
KW |
67.14 |
81.53 |
99.19 |
117.28 |
129.06 |
148.68 |
153.9 |
198.12 |
|
Cooling capacity (50HZ) |
Kcal/h |
57748 |
70120 |
85303 |
100869 |
110984 |
127868 |
132359 |
170383 |
|
Total input power |
KW |
17.3 |
21.3 |
25.6 |
29.4 |
33.1 |
38.6 |
42.5 |
59 |
|
Max running current |
A |
42.1 |
48.5 |
58.3 |
65.4 |
75.4 |
80.6 |
88.4 |
101.92 |
|
Power supply |
- |
3N-380V-50HZ |
Same |
Same |
Same |
Same |
Same |
Same |
Same |
|
Refrigerant |
- |
R22 |
R22 |
R22 |
R22 |
R22 |
R22 |
R22 |
R22 |
|
Refrigerant charge |
KG |
5*2 |
6.3*2 |
5*3 |
6.2*3 |
5*4 |
5.6*4 |
5*5 |
6.24*5 |
|
Refrigerant control |
- |
External balance thermal expansion valve |
Same |
Same |
Same |
Same |
Same |
Same |
Same |
|
Compressor type |
- |
Hermetic scroll or piston |
Same |
Same |
Same |
Same |
Same |
Same |
Same |
|
Compressor power |
KW |
7.5*2 |
9.4*2 |
7.5*3 |
9*3 |
7.5*4 |
9*4 |
7.5*5 |
9*5 |
|
Cooling water flow |
M³/h |
14.44 |
17.54 |
21.32 |
25.22 |
27.74 |
31.98 |
33.09 |
41.6 |
|
Cooling water pressure drop |
Kpa |
38 |
30 |
36 |
37 |
35 |
40 |
42 |
45 |
|
Cooling water pipe size |
- |
G2" |
G2" |
G2-1/2" |
G2-1/2" |
G3" |
G3" |
G3" |
G3" |
|
Chilled water flow |
M³/h |
11.55 |
14.03 |
17.06 |
20.18 |
22.19 |
25.58 |
26.48 |
33.28 |
|
Chilled water tank |
M³ |
0.33 |
0.405 |
0.55 |
0.55 |
0.61 |
0.61 |
0.71 |
0.71 |
|
Chilled water pipe size |
- |
G2" |
G2" |
G2-1/2" |
G2-1/2" |
G2-1/2" |
G2-1/2" |
G2-1/2" |
G3" |
|
Water pump power |
KW |
2.2 |
2.2 |
2.2 |
4 |
4 |
4 |
4 |
4 |
|
Water pump pressure |
Kpa |
220 |
220 |
250 |
250 |
250 |
250 |
250 |
250 |
|
Length |
MM |
1680 |
1880 |
2190 |
2190 |
2200 |
2200 |
2200 |
2400 |
|
Width |
MM |
770 |
914 |
990 |
990 |
1000 |
1070 |
1070 |
1150 |
|
Height |
MM |
1470 |
1790 |
1800 |
1800 |
1940 |
2100 |
2100 |
2200 |
|
Weight |
KG |
440 |
620 |
690 |
760 |
850 |
950 |
1000 |
1100 |
Hot Tags: water chiller cooler, China water chiller cooler manufacturers, factory